Re: [uCsimm] HV capacitors on the LAN transformer

From: Daniel Haensse (daniel.haensse@fhk.usz.ch)
Date: Thu Aug 16 2001 - 02:15:00 EDT


Hi Chris

Am Mit, 15 Aug 2001 schrieben Sie:
> Transients of hundreds of volts also occur in category 5 cables due to
> triboelectric effects and static buildup. It's a big problem in the networks
> in large buildings with thousands of meters of wiring. The caps really
> should be there for noise immunity, and they really do need to be high
> voltage if you are running more than a few meters of cable.
well, don't you think using a switch will solve the problem as well. The uCSimm
does not have all the pins of the magnetics broad out. So the capacitors can't
be connected.

Dani